DESIGN DATA:
Bore Well Water Quality
SL Parameter Unit Value
01 pH 7
02 Turbidity NTU 10
03 Total Alkalinity ppm 60
04 Total Hardness ppm 180
05 Calcium ppm 135.07
06 Magnesium ppm 14.83
07 Total Iron ppm 1.7
08 Chloride ppm 50
09 TDS ppm 295
10 Sulphate ppm 10
Treated Water Quality
SL Parameters Unit Value
01 Service Cycle Hrs 12
02 O.B.R. Cu mtr 900-1000
03 pH 6.8-7
04 Turbidity NTU <1
05 TSS ppm <1
06 Total Hardness ppm <5
07 Total Iron ppm NIL
08 Sulphate ppm 9-10
FLOW CHART:
In--- Online Lime Doser --- Aeration Tank with rotary type air blower --- Pump---Iron Filter ---- Softener—Treated Water Tank
UNITS OF THE SYSTEM PROPOSED:
Sr No Item Specification Qty Amount(Rs.)
1 Online Lime Doser with storage tank 01
2 Aeration tank RCC Tank 01
3 Rotary type air blower aeration grid in aeration tank 01
4 Main Water pump from aeration tank to Iron Filter 1W+1S
5 Pipe and Fittings LOT
6 Iron removal filter 80.00 CuM / Hr 01
7 Water Softener, 1000 CuM / Regn. @ 180 ppm rwh, 80 CuM / Hr 01
8 Treated Water Tank RCC Tank 01 OPTIONAL
NOTE:
The iron removal depends upon dissolved oxygen present in water. Please make sure that the raw water has at least 0.4 ppm dissolved oxygen. Failing which, an aeration system will be added to the Iron removal plant as mentioned in item no 2 & 3 .
So, testing of water sample is the first step.
Thanks & Regards,
Yours Truely,
Envo Projects
(saleem asraf)
9899300371
TECHNICAL DATA SHEET : Iron Removal Filter
SPECIFICATIONS
- One mild steel welded construction pressure vessel fitted internally, with raw water distribution and filtered water collection system, supporting legs / brackets etc. Necessary manholes and nozzles for inlet, outlet, air release etc. provided on the shell, coated internally with two coats of epoxy paint and externally with two coats of red iron oxide / zinc chromate primer.
- One set of frontal pipe and valves network for operation and control.
- One charge of fresh under bed ( filter media ) topped CATALYST IRON REMOVAL MEDIA
INSTRUMENTATION
- Pressure gauges and sample points at inlet and outlet.
TECHNICAL DATA
Sl.No. Description Data
1. Plant Model : APRO 3000 IRFD
2. Unit diametre mm : 3000
3. Unit H.O.S. mm : 1500
4. Pipe work : MS ERW Black Class ‘B’ all flanged
5. Valves : C.I. Butterfly
6. Size mm NB : 150
7. Filter media : Natural gravel and quartz sand
8. Adsorbent media : CATALYST IRON REMOVAL MEDIA
9. Quantity of adsorbent media Ltrs. : 7000
OPERATIONAL DATA
1. Max. working pressure kgs. / cm2 : 3.5
2. Min. working pressure kgs. / cm2 : 1.0
3. Max. rate of flow m3 / Hr. : 100.0
4. Min. rate of flow m3 / Hr. : 10.0
5. Backwash flow rate m3 / Hr. : 150
6. Backwash period minutes : 15-20
7. Rinse flow rate m3 / Hr. : 50.0
8. Rinse period minutes : 5-10
9. Treated water quality : Dissolved Iron less than 0.1 ppm
TECHNICAL DATA SHEET : DOWNFLOW WATER SOFTENING PLANT
SPECIFICATIONS
- One mild steel welded construction pressure vessel fitted internally with strainer plate at the bottom, raw water and brine distributors at the top and externally with necessary manholes, nozzles for inlet, outlet, air release, resin outlet etc. The vessel coated internally with two coats of anticorrosive epoxy paint and externally with two coats of red iron oxide / zinc chromate primer.
- One open MSRL tank of adequate capacity for brine preparation and measurement. One no. air distributor laid at the bottom for air agitation. The brine tank provided with valves for drain, brine outlet.
- One set of frontal pipe and valves network for operation and control. Pipe work fabricated from MS ERW Black Class ‘B’ pipe and valves to be C.I. diaphragm.
- One set of regeneration assembly comprising of power valve, ejector, brine valve and brine suction line etc. all incorporated into the main pipe work.
- One set of salt saturation system comprising of air blower, air distributor and the interconnecting pipe connection.
- One fresh charge of Ion Exchange Resin ( INDION - 220 Na / Imported Resin ).
- One pressure gauge at inlet and outlet each. One sampling point at outlet.
TECHNICAL DATA
Sl.No. Description Data
1. Plant Model : APRO – 1850 - SDZ
2. Plant Diametre mm : 1850
3. Plant H.O.S. mm : 2600
4. Brine Tank Capacity Ltrs. : 3500
5. Pipework and Valves size mm NB : 150
6. Quantity of Resin Ltrs. : 4000
OPERATIONAL DATA
1 Maximum Treatment Flow m3 / Hr. : 100.00
2 Minimum Treatment Flow m3 / Hr. : 10.00
3 Designed Treatment Flow m3 / Hr. : 80.00
4 Regenerant Required : NaCl - Common Salt
5 Quantity Required per Regeneration : 600 kgs.
6 Treated Water Hardness : Below 5 ppm
7 Net output per Regeneration m3 : 1000 M³ at 180 ppm
COPY RIGHTS : TO AVOID COPYRIGHT VIOLATIONS, ALL POSTS ARE SHOWN ALONG WITH SOURCES FROM WHERE ITS TAKEN. PLEASE CONTACT ME IN MY EMAIL SALEEMASRAF@GMAIL.COM , IF YOU ARE THE AUTHOR AND YOUR NAME IS NOT DISPLAYED IN THE ARTICLE.THE UNINTENTIONAL LAPSE ON MY PART WILL BE IMMEDIATELY CORRECTED.
I HAVE SHARED ALL MY PRACTICAL WATER TREATMENT EXPERIENCES WITH SOLVED EXAMPLE HERE SO THAT ANYBODY CAN USE IT.
SEARCH THIS BLOG BELOW FOR ENVO ,COMPACT STP,ETP,STP,FMR,MBBR,SAFF,IRON,ARSENIC,FLUORIDE,FILTER,RO,UASB,BIO GAS,AERATION TANK,SETTLING TANK,DOSING,AMC.
SEARCH THIS BLOG
Tuesday, January 16, 2007
WATER TREATMENT OF BORING WATER FOR IRON & HARDNESS
Environmental Entrepreneur,Green Biz.NRN Murthy of Infosys says that we Indians are weak in execution.We need to realize the need and practice of gud project management. Form a group of competent Managers,Give them responsibilities and review the project from day One.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment