HOW TO DESIGN A STP USING MBBR FBBR FMR TECHNOLOGY



An introduction to MBBR (moving bed biofilm reactor )/ FM Reactor/ FAB /FMR Reactor wastewater treatment

When communities of microorganisms grow on surfaces, they are called biofilms. Microorganisms in a biofilm wastewater treatment process are more resilient to process disturbances compared to other types of biological treatment processes.  Thus, biofilm wastewater treatment technologies can be considerably more robust especially when compared to conventional technologies like activated suldge process..
In the MBBR biofilm technology the biofilm grows protected within engineered plastic carriers, which are carefully designed with high internal surface area. These biofilm carriers are suspended and thoroughly mixed throughout the water phase. With this technology it is possible to handle extremely high loading conditions without any problems of clogging, and treat industrial and municipal wastewater on a relatively small footprint.

System description

The MBBR™ biofilm technology is based on specially designed plastic biofilm carriers or biocarriers that are suspended and in continuous movement within a tank or reactor of specified volume. The design of associated aerators, grids, sieves, spray nozzles and other integral parts to the reactor is also of great importance in making up the system as a whole .
The industrial and municipal wastewater is led to the MBBR™ treatment reactor where biofilm, growing within the internal structures of the biocarriers, degrade the pollutants.  These pollutants that need to be removed in order to treat the wastewater are food or substrate for growth of the biofilm.  The biocarrier design is critical due to requirements for good mass transfer of substrate and oxygen to the microorganisms  .  Excess biofilm sloughs off the biocarrier in a natural way .

An aeration grid located at the bottom of the reactor supplies oxygen to the biofilm along with the mixing energy required to keep the biocarriers suspended and completely mix within the reactor.

Treated water flows from reactor through a grid or a sieve, which retains the MBBR™ biocarriers in the reactor. Depending on the wastewater, the reactors are may be equipped with special spray nozzles that prevent excessive foam formation.

The MBBR is a biological aerobic degradation of organic pollutants. The process utilizes millions of tiny, polyethylene biofilm elements that provide a high surface area as a home for a vast, highly active bacteria culture. This fixed film process features a flexible reactor design, the ability to handle load increases without the need for extra tankage, and remains stable under large load variations, including temperature, strength or pH. Like the activated sludge process, the MBBR process utilizes the whole volume of an open tank. Unlike an activated sludge reactor, it does not require sludge return to operate effectively. In MBBR , addition of media quantity and Air Quantity is the Key Factor.

Total reactor volume of the MBBRs is designed for different hydraulic retention time for different types of waste water at average flows and than checked against peak flows. Essentially nutrient levels and DO levels are the only control points for the system.



Moving Bed Biofilm Bioreactor (MBBR) process uses the whole tank volume for biomass growth. It uses simple floating media, which are carriers for attached growth of biofilms. Biofilm carrier movement is caused by the agitation of air bubbles. This compact treatment system is effective in removal of BOD as well as nitrogen and phosphorus while facilitating effective solids separation.

Design and Construction Principles

Neutralised and settled wastewater passes through MBBR for reduction in BOD/COD. Most of the MBBR plants are provided with vertically or horizontally mounted rectangular mesh sieves or cylindrical bar sieves. Biofilm carriers are made up of high density (0.95 g/cm3) polyethelene. These are normally shaped as small cylinders with a cross inside and fins outside. The standard filling of carrier is  not more than 465 m2/m3. Generally, design load for COD-BOD removal is 20 g COD / m2d. Smaller carriers need smaller reactor volume at a given loading rate (as g/m2d) when the carrier filling is same. 

It is advisable to use MBBR in combination with a DEWATS  as a pre-treatment unit, depending on the local conditions and input characteristics. It is a very robust and compact alternative for secondary treatment of municipal wastewater, having removal efficiency for BOD 90 – 95% (low rate) and that of 75 – 80% for high rate. Average nitrogen removal is about 85%. There is no need for sludge recirculation. Phosphorus and faecal coliform reduction is feasible with additional passive (non-mechanical) or active (mechanical) system components.

A constantly operating MBBR does not require backwashing or return sludge flows. It has minimal head-loss. Coarse-bubble aeration in the aeration zone in the wastewater treatment tank provides ease of operation at low-cost. Agitation continuously moves the carrier elements over the surface of the screen thus preventing clogging. Maintenance of MBBR system includes screening, influent equalisation, clarifier system, sludge handling and integrated control system. There is no need to maintain f/M ratio as there is self-maintenance of an optimum level of productive biofilm. Skilled labour is required for routine monitoring and operations of pumps and blowers.


Calculations!:Aeration Tank Volume, HRT, MLSS Values.
I am working in a STP & ETP plant. I need to know how to calculate:

1. Volume of Aeration tank
2. HRT
3. F/M Ratio
4. MLSS value.

The relevant details of the ETP are as below:

Influent flow = 10 m3 / day
In. flow BOD = 1200 mg / L
In.flow COD = 2200 mg / L
TSS  = 850 mg / L

  Jeyaroopa
  jeyaroopa79@gmail.com
Dear Jayroopa

You may please refer Water & Waste Water Engineering by Metcalf & Eddy.
BOD of effluent is 1200 mg/l. It will be difficult to bring down the BOD by Activated Sludge process to desire permissible limits.

Simplified method of calculation is as below.

Process Activated sludge
Flo3, CUM 10
Type Extended aeration
Food to Microorganism ratio (F/M) 0.15
Total BOD load, Kg BOD*Flow/1000.= 12
Total mixed liquor suspended solids(MLSS) Total BOD/(F/M) = 80 kg
MLSS in Tank say mg/l 3000
Volume of tank, CUM Total MLSS/(MLSS/1000) = 26.6
Retention time, hr 24*Volume of Tank/Flow = 63.84

You can select F/M & MLSS values and optiimise the volume of a tank.
The waste water has high suspended solids therefore sedimentation is must.

Maximum efficiency of Activated sludge process is 95% therefore if you need lower value of BOD in treated effluent then you have to opt two stage process.
For further information please contact

Prof. R. V. Saraf
Director
Viraj Envirozing India Pvt. Ltd.
21 Radhakrishna Near SBI, Paud Road, Pune 38
watersgs@vsnl.net

13 Aug, 2008   |  Taral Kumar


Dear Jeyaroopa,

Though the calculation is not that simple, I will give you a thumb rule. Multiply BOD with Quantity of effluent and divide it by 500 to get aeration tank volume. For example, for 10 cum/day with 1200 BOD, aeration tank volume shall be 10 x 1200 / 500 = 24 cum. That is 2.5 days storage nearly. But that is because the BOD is excessively high.

With best regards,

Taral Kumar
Executive Director
Akar Impex Pvt. Ltd.
Noida, Uttar Pradesh


Friday, May 27, 2016

Moving Bed Biofilm Bioreactor (MBBR) -Design and Construction Principles of FMR






Moving Bed Biofilm Bioreactor (MBBR) process uses the whole tank volume for biomass growth. It uses simple floating media, which are carriers for attached growth of biofilms. Biofilm carrier movement is caused by the agitation of air bubbles. This compact treatment system is effective in removal of BOD as well as nitrogen and phosphorus while facilitating effective solids separation.

Design and Construction Principles

MBBR units are placed in series based on the load entering each reactor. Neutralised and settled wastewater passes through MBBR for reduction in BOD/COD. Most of the MBBR plants are provided with vertically or horizontally mounted rectangular mesh sieves or cylindrical bar sieves. Biofilm carriers are made up of high density (0.95 g/cm3) polyethelene. These are normally shaped as small cylinders with a cross inside and fins outside. The standard filling of carrier is below 70% with a maximum specific area not more than 465 m2/m3. Generally, design load for COD-BOD removal is 20 g COD / m2d. Smaller carriers need smaller reactor volume at a given loading rate (as g/m2d) when the carrier filling is same. 

It is advisable to use MBBR in combination with a septic tank, DEWATS or a pre-coagulation step as a pre-treatment unit, depending on the local conditions and input characteristics. It is a very robust and compact alternative for secondary treatment of municipal wastewater, having removal efficiency for BOD 90 – 95% (low rate) and that of 75 – 80% for high rate. Average nitrogen removal is about 85%. There is no need for sludge recirculation. Phosphorus and faecal coliform reduction is feasible with additional passive (non-mechanical) or active (mechanical) system components.

A constantly operating MBBR does not require backwashing or return sludge flows. It has minimal head-loss. Coarse-bubble aeration in the aeration zone in the wastewater treatment tank provides ease of operation at low-cost. Agitation continuously moves the carrier elements over the surface of the screen thus preventing clogging. Maintenance of MBBR system includes screening, influent equalisation, clarifier system, sludge handling and integrated control system. There is no need to maintain f/M ratio as there is self-maintenance of an optimum level of productive biofilm. Skilled labour is required for routine monitoring and operations of pumps and blowers.

You always need expert advise to design a efficient and cost effective system.


ITEMS OF ENVO COMPACT MODULE 



Sr No
Item
Specification
Qty
Cost
1
Raw Sewage Pump
Submersible,auto running,kirlosker
1 No
2
Compact module consisting of following units,.
1.Aeration-I with aeration grid
2.Aeration-II with aeration grid
3.Tube settler with baffle and weir
4.Treated water tank
5.Sludge holding tank with aeration
MS with support frame, inside FRP, outside painted
LOT
3
Diffuser in Aeration Tank-I & II
Dome type,Make:ENVO
LOT
4
Floating Media in aeration tank-I & II

LOT
5
Tube Deck Media in Tube Settler

LOT
6
Air Blower,
Twin lobe Rotary type, Make: SGN
1 No
7
Filter Feed Pump
Kirlosker
1 No
8
Pressure sand  filter
MS module with media and frontal pipes and valves,Make:ENVO
1No
9
Activated carbon filter
MS module with media and frontal pipes and valves,Make::ENVO
1No
10
Electric starters,wires
Panel,starter  and wires to pump and blowers
LOT
11
Pipe & Fittings, PVC
PVC pipe and fittings
LOT
12
Sludge Pump
kirlosker pump
1 No
13
Filter Press
PP plates with filter cloth, Make:Saraswati
1 No
14
Erection commissioning of the system
LOT

Saturday, July 19, 2008

UPGRADATION OF THE EXISTING SEWAGE TREATMENT PLANT (STP)


UPGRADATION OF THE EXISTING SYSTEM
:
POINT ONE
: FMR technology in place of existing conventional Activated Sludge System
Utilizing FMR technology can dramatically increase the efficiency of the Aeration system. Compared to conventional technologies the FMR is compact, energy efficient and user friendly. It also allows flexibility in design of the reactor tank.
The FMR is better than SAFF technology and works on the same principle as the submerged fixed film process (SAFF) with only one exception - the media is not fixed and floats around in the aeration tank. The main advantage of this system over the submerged fixed film process is that it prevents choking of the media.

FMR is an advanced version of the SAFF, which uses a floating media to avoid the practical choking problem of media in SAFF.

POINT TWO
:
The existing Sludge drying beds can be replaced with sludge thickener and centrifuge which is faster and efficient for disposal of sludge. It is also hygienic in view of five star hotel.

Sludge Thickening
:
Gravity thickening is accomplished in circular sedimentation basins similar to those used for primary and secondary clarification of liquid wastes
The sludge thickener shall be used to store and gravity thickens sludges from the waste treatment processes. Settled sludges are discharged on an as needed via sludge pumps. Water content in sludge can be reduced by mechanically compressing sludge in filter press, belt press etc. this can also be achieved by centrifuge mechanism and also by other mechanical devices. Excess supernatant wills gravity flow from the tank with provisions for manual decanting of waters via valves located on the side of the tank.
The Area Requirement of Sludge Thickener and Centrifuge:
Both the above items can be installed in the area presently occupied by sludge drying beds. No extra area is required.


POINT THREE
: The media in ACF and PSF are to be changed as they have losed filtration capacity. They have not been changed for a long time. POINT FOUR : The treated water after ACF can be passed through a Softener so that this water can be used in Cooling tower therby reducing consumption of ground water.
Saleem Asraf Syed Imdaadullah
Envo Projects
Mobiles : 9899300371
311/22,Zakir Nagar,New Delhi-110025
email: saleemasraf@gmail.com
web: http://saleemindia.blogspot.com

Saturday, April 21, 2007

Fluidised Media Reactor (FMR)

The INDION Fluidised Media Reactor (FMR) uses the attached growth process for waste water/sewage treatment and recycle. It incorporates a single tank unit, consisting of a bar screen chamber, specially designed floating media to facilitate the attached growth process, oxygen transfer through diffused membrane aeration, lamella settler and chlorine contact tank. The system is available in mild steel and reinforced concrete.

The FMR works on the same principle as the submerged fixed film process with only one exception - the media is not fixed and floats around in the aeration tank. The main advantage of this system over the submerged fixed film process is that it prevents choking of the media. This also avoids sludge recirculation. Compared to conventional technologies the FMR is compact, energy efficient and user friendly. It also allows flexibility in design of the reactor tank. The advantages of the INDION FMR are many –

Unique single tank design, no moving parts & easy maintenance.

Attached growth process, with specially designed moving media.

Compact and modular design.

Minimal pumping and chemical cost, low operating cost.

Flow rate for sewage treatment exceeding100 m3/d.

Applications of FMR include decentralised compact sewage plants for housing complexes, hotels, commercial complexes, industries and rural communities. It can also be used in industrial waste treatment in industries such as food & beverage, textile, pulp & paper, chemicals, pharmaceuticals, petrochemicals and dairy production.

Orders for the INDION fluidised media bed reactor for sewage treatment include Reliance India Ltd., ICC – Pune, SDM Technoengrs (Satyam Computers) and JK Cement, Rajasthan