COPY RIGHTS : TO AVOID COPYRIGHT VIOLATIONS, ALL POSTS ARE SHOWN ALONG WITH SOURCES FROM WHERE ITS TAKEN. PLEASE CONTACT ME IN MY EMAIL SALEEMASRAF@GMAIL.COM , IF YOU ARE THE AUTHOR AND YOUR NAME IS NOT DISPLAYED IN THE ARTICLE.THE UNINTENTIONAL LAPSE ON MY PART WILL BE IMMEDIATELY CORRECTED.

I HAVE SHARED ALL MY PRACTICAL WATER TREATMENT EXPERIENCES WITH SOLVED EXAMPLE HERE SO THAT ANYBODY CAN USE IT.

SEARCH THIS BLOG BELOW FOR ENVO ,COMPACT STP,ETP,STP,FMR,MBBR,SAFF,IRON,ARSENIC,FLUORIDE,FILTER,RO,UASB,BIO GAS,AERATION TANK,SETTLING TANK,DOSING,AMC.

SEARCH THIS BLOG

Wednesday, February 29, 2012

DAF Clarifier in Paper Mill waste water

FLOTATION PROCESS
DAFTECH Floatcells are circular in shape, ranging in diameter from 1.2 to 21.3 meters and a liquid depth of only 0.65 meter. The complete set up consists of a flotation tank, feed pump, pressure pump, compressor, air mixing tube, chemical feed system and a spiral scoop for collection and removal of floated sludge.

The inlet, outlet and sludge removal mechanisms are contained in the central rotating section. This section and the spiral scoop rotate around the tank at a speed synchronized with the flow. The system is operated in the recycle flow pressurization mode where a portion of clarified effluent (25 - 30 percent) is continuously recycled from the collection tank to the air mixing tube at about 6.5 bar pressure. After pressure release, the aerated water is mixed with the influent flow just before the inlet to the distribution duct that moves with the same velocity, but in opposite direction to the incoming flow thus creating a quiescent state in the flotation chamber. Fine bubbles generated in this manner attach to the suspended particles and make them float to the surface.

The spiral scoop takes up the floated sludge, pouring it into the stationary center section where it is discharged by gravity. Clarified water is removed by extraction pipes, which are attached to the moving center section and discharged. Wiper blades attached to the moving distribution duct scrape the bottom and the sides of the tank and discharge settled sludge into the built-in sump for periodic purging. The variable speed gear motor drives the rotating elements and scoop. Electrical current for the gear motor is fed from a rotary contact mounted on the central shaft.


AIR MIXING
The separation efficiency of Total Suspended Solids in a DAF cell depends substantially on the generation of uniformly sized microscopic air bubbles. 

A part of the clarified water, generally 25 to 30% of the feed rate, is pressurized through a centrifugal pump to about 65 meter head and let into a cylindrical Air Mixing Tube through a nozzle at one end. The nozzle is so oriented inside the tank that the jet of water churns spirally along the inside wall of the tube forming a vortex along the central axis of the tube.

Into this tube is brought compressed air which passes through a microscopically porous medium placed adjacent to the inside wall of the tube.

The tube produces a saturated air-water mixture because the rate of absorption of any gas in a liquid is directly proportional to the pressure in which the dissolution takes place.

The air-water mixture that comes out of the other end of the tube passes through a pressure release valve where the pressure is reduced to the level of the incoming wastewater feed. At this stage, air bubbles of 30 - 50 microns are produced profusely which get released into the wastewater thereby giving the necessary buoyancy
to the suspended solids to rise to the surface of the water in the flotation tank.


ZERO VELOCITY
A quiescent state is an absolute necessity for good flotation. This is achieved by ensuring zero velocity of the wastewater when it enters the flotation tank.

The feed of wastewater premixed with depressurized recycle stream is led into the main tank through a distribution tube with adjustable nozzles. It is then discharged into the tank through baffles and then a turbulence arrester. The rotational velocity of the incoming wastewater into the tank is counterbalanced by the mechanical movement of the distribution tube in the opposite direction but at the same speed. This ensures quiescent condition and minimum turbulence.

DAFTECH Floatcells are designed with a retention time of 3 minutes. The equipment therefore is much more compact than rectangular DAF clarifiers of 15 to 30 minutes of retention and occupies only half of the floor space.
 
1 Wastewater Inlet 7 Floatcell Wall 13 Wastewater Pump
2 Clarified Water Outlet 8 Tank Wall Support 14 Air Compressor
3 Floated Sludge Outlet 9 Rotating Tank Wall 15 Flocculant Feed Point
4 Clarified Water Recycle Outlet 10 Level Control Weir 16 Pressure Release Valve
5 Rotary Joint 11 Spiral Scoop 17 Purge Valve
6 Spiral Scoop Shaft 12 Recycle Pump 18 Sample Point
Daftech Engineers Pvt. Ltd.,
SCO 1A, Sector 7-C, Madhya Marg

Chandigarh - 160 019
INDIA

Tuesday, February 28, 2012

MSW CONSULTANT

Plastic waste recycling industry in DELHI : The quantity of plastic wastes generated in Delhi is estimated to be 300 mt per day.Plastic waste collection and segregation, recycling and reprocessing systems and promoting end-product applications with desired recyclable component based on Guidelines for Recycling of Plastics to be issued by the Bureau of Indian Standards.
we do consultancy for that.

Recycling of plastic

I wonder how will I be able to do away with this cheapest and lightest means of carrying my luggage.

These plastic bags and bottles have been our greatest friends in routine life. But, these friends of ours are severely putting a strain on the environment. Discarding plastic waste in open chokes the water bodies, clogs soil pores, blocks the drainage system. Not only this, the plastic waste when gets mixed and clogged with other waste emits harmful gases. If the same plastic becomes the food for fish, it means only death for them.

What can be done to reduce the side effects of plastic waste? Recycling of plastic is the best way to reduce the burden on the environment. Lets begin with not throwing the plastic bottles and bags in open. Secondly, make use of the use-and-throw bottles after cleansing them and re-using them for some other purpose.